technokasce.blogg.se

Hp dl360 g6 hp firmware dvd
Hp dl360 g6 hp firmware dvd













  1. #HP DL360 G6 HP FIRMWARE DVD INSTALL#
  2. #HP DL360 G6 HP FIRMWARE DVD UPDATE#
  3. #HP DL360 G6 HP FIRMWARE DVD LICENSE#
  4. #HP DL360 G6 HP FIRMWARE DVD FREE#

#HP DL360 G6 HP FIRMWARE DVD UPDATE#

If it still doesn't work, download the "Smart Update Firmware DVD", actual is V. If yes, everything must work in your case. Have you made a RAID1 Array into the P410 Controller BIOS (F8 after the red-written text Smart Array bla bla). Comes with just 6GB of RAM, but 24GB additional Kingston RAM KTH-P元13K3/24G are around USD 350 (or double if you want original RAM from HP wich includes on-site support in an event of failure). PS: If you can get model 470065-537, it comes with just one Six-Core E5645 and you can expand later with another Six-Core E5645. Only "disadvantage" of the D元80 is that it comes with 8 x 2.5" SFF Harddisk Trays (can be upgraded to 16 x 2.5" SFF Trays) and HDDs with the same Space are more expensive in 2.5" SFF instead of 3.5" LFF, but the smaller make less noise.

hp dl360 g6 hp firmware dvd

#HP DL360 G6 HP FIRMWARE DVD INSTALL#

Add in values for temperature measurement, cost per kWh and a currency, and it will reveal a table of projected costs and potential savings.Buy the D元80G7, I didn't regret this decision the last six times.Ĭosts (here in Switzerland) LESS than the DL180 and has FOUR NICs, not "just" two like the DL180.įurthermore it has 9 DIMM Slots per CPU Socket, DL180 just 6, so you can cheaper upgrade RAM if you want.Īs mentionned from the posters above, the D元80 has the P410i Smart Array Controler by default on Board, and normally 256 to 512MB BBW Cache (important for speed and the ability to install ESXi 4.x or 5). It’s worth the effort, though, as the SIM interface is updated with tools showing graphs of power consumption, inlet air temperature and CPU performance.

#HP DL360 G6 HP FIRMWARE DVD LICENSE#

It was a tricky to set up, since the review server’s iLO2 firmware had to be upgraded to support it, the Power Manager 2 Windows service had to be downloaded and installed, and then we had to license it and apply these to each server we wanted to control. Functioning as a plugin to its Systems Insight Manager, the Insight Power Manager provides tools for monitoring and controlling power consumption and thermal output. HP’s Insight Control server management tools are among the best on the market, and power is now a high priority. With SiSoft Sandra maxing out all eight logical cores this peaked at a modest 157W. HP has done a good job in reducing power demands, with our inline power meter recording a draw of only 7W in standby and 100W with Windows Server 2003 R2 running in idle. HP’s Thermal Logic uses up to 32 sensors to monitor power consumption, and the supplies share a common slot type so you can choose from three different outputs. The D元60 supports two hot-plug supplies, and HP claims the D元60 and D元80 G6 are the only servers currently in the Energy Star program.

#HP DL360 G6 HP FIRMWARE DVD FREE#

They’re a waste of space and removing them would free up enough room for more network ports.

hp dl360 g6 hp firmware dvd

We were surprised to see PS/2 mouse and keyboard ports at the rear, making HP one of the last main vendors to still provide these. Dell has taken the same tack with the R610, but goes one step beyond with its Lifecycle Controller – an embedded chunk of NVRAM, which can be used to boot the server into Dell’s UEFI interface.ĭell outdoes HP for network connections, as the D元60 has only two Gigabit ports whereas the R610 has a pair of embedded dual-port adapters. Virtualisation is a high priority, and HP has included an SD memory card slot on the motherboard for booting embedded hypervisors.

hp dl360 g6 hp firmware dvd hp dl360 g6 hp firmware dvd

We were impressed with the low noise levels, putting the D元60 on a par with the R610 and its near-silent runnings. Adding the second processor requires a fourth module to be plugged in behind it. In base models, cooling is handled by three hot-plug modules, each with a pair of dual-rotor fans. Be careful if you remove this, we found it difficult to reposition. The D元60 has a tidy interior with the two processor sockets and their attendant bank of nine DIMM sockets covered in a plastic shroud to improve airflow. An optional battery backup is available, and you can upgrade cache memory to 512MB. The system starts with no extra cache memory and supports stripes and mirrors, but the review unit included the 256MB cache module that fits in a dedicated slot and adds support for RAID5.















Hp dl360 g6 hp firmware dvd